For Research Use Only — Not for Diagnostic Procedures

Mag Pro-32: Automated Nucleic Acid Extraction for 32 Samples

32 samples in 15–40 minutes. Walk-away protocol. Validated for LAMP and PCR workflows (manufacturer-stated).

check_circle 32 Samples Per Run check_circle Built-In UV Decontamination check_circle LAMP-Validated Kits
Mag Pro-32 automated nucleic acid extraction instrument
verified_user

Validated Performance

LAMP, PCR & RT-PCR workflows (manufacturer-stated)

biotech 32 Samples Per Run
clean_hands Built-In UV Decontamination
science LAMP-Validated Kits
security Research Use Only

Streamlined Workflow

Automated extraction in three simple steps — designed for research lab efficiency.

01
inventory_2

Load Samples

Place up to 32 samples into the tray using pre-loaded reagent plates — no manual pipetting of individual tubes required.

02
settings_input_component

Select Protocol

Choose from pre-loaded protocols on the tablet touchscreen — select your sample type and press start.

03
directions_walk

Walk Away

The Mag Pro-32 handles binding, wash, and elution automatically — then runs the UV sterilization cycle. Completes in 15–40 minutes (manufacturer-stated).

Why Labs Choose the Mag Pro-32

32 Samples / Run

Process Your Entire Batch Simultaneously

Handles up to 32 samples in one automated run — no batching, no serial processing, no waiting.

UV Decontamination

Built-In UV Lamp Runs After Every Batch

UV sterilization cycle built in as standard — no manual wipe-down required between batches for LAMP and PCR applications.

Validated Workflows

LAMP, Real-Time PCR, and RT-PCR

With PLM-2007 kits, validated for three downstream molecular applications (manufacturer-stated).

Customizable

Flexible Protocols via Tablet Interface

Multiple built-in purification procedures selectable from a tablet — configure for your sample type without a service call.

Designed for Your Role

Automate 32-Sample Extractions in 15–40 Minutes — Reclaim Bench Time Without a Six-Figure Platform

Your lab's molecular workflow runs on extraction purity. Manual magnetic bead protocols are reliable — until volume scales, staff turns over, or one tired tech produces a batch that tanks your downstream assay. The Mag Pro-32 removes operator variance: load 32 samples, select a protocol, and walk away. Validated for LAMP, real-time PCR, and RT-PCR (manufacturer-stated). No enterprise price tag.

  • check_circle32 samples per run, 15–40 minutes — replaces hours of manual bench time (operator-dependent)
  • check_circleBuilt-in UV lamp — cross-batch contamination control built in, not bolted on
  • check_circleValidated for LAMP, PCR, and RT-PCR — three downstream applications (manufacturer-stated)

Standardize Extraction Across Your Entire Team — One Protocol, 32 Samples, No Operator Variance

Manual extraction means your team's results are only as consistent as your most experienced tech — and that consistency walks out the door when someone leaves. The Mag Pro-32 locks in your protocol: tablet interface, selectable purification procedures, UV decontamination cycle built in. New tech, same result. Validated for LAMP, PCR, and RT-PCR (manufacturer-stated).

  • check_circleAutomated operation eliminates operator-to-operator variance
  • check_circlePre-loaded reagent plates reduce pipetting steps and preparation errors
  • check_circleTablet interface with selectable protocols — minimal training required

Load 32 Samples, Press Start — Free Your Hands for Work That Matters

Manual magnetic bead extraction for 32 samples is hours of repetitive pipetting (operator-dependent). The Mag Pro-32 automates the extraction run — pre-loaded reagent plates, automated binding, wash, and elution — while you do something else. Built-in UV lamp handles decontamination. Validated for LAMP, PCR, and RT-PCR (manufacturer-stated).

  • check_circle32 samples per automated run, 15–40 minutes (manufacturer-stated)
  • check_circlePre-loaded reagent plates reduce manual pipetting steps
  • check_circleProtective probes reduce cross-batch contamination — standard on every run

Validated Compatible Kits

Extraction kits validated for use with the Mag Pro-32 instrument (manufacturer-stated).

PLM-2007
RNA Extraction

Mag Pro Plus Automated RNA Extraction Kit

Pre-loaded 32T extraction plates designed for the Mag Pro-32 — validated for LAMP, real-time PCR, and RT-PCR (manufacturer-stated).

Details
PLM-2009-32T
Virus DNA/RNA

Mag Pro Virus DNA/RNA Extraction Kit

96-well deep well plate format for viral nucleic acid extraction — compatible with the Mag Pro-32 instrument.

Details
PLM-2000
RNA Extraction

Pro-Mag™ RNA Extraction Kit

100-prep RNA extraction kit — silica magnetic beads, validated for LAMP and PCR workflows.

Details

Technical Specifications

Specification Value
Catalog NumberPLM-NPA-32
Product TypeAutomated Nucleic Acid Extraction Instrument
RUO DesignationFor Research Use Only — Not for Diagnostic Procedures
Sample Throughput1–32 samples per run
Extraction Time15–40 minutes (protocol-dependent)
Sample Volume Range20–1,000 µL
Magnetic Bead Efficiency>98% (manufacturer-stated)
InterfaceTablet touchscreen
UV SterilizationBuilt-in UV lamp
Heating ModuleYes (lysis and elution)
Protective ProbesYes
Dimensions (L×W×H)~430 × 395 × 435 mm*
Weight~32.5 kg*
Compatible KitsPLM-2007, PLM-2009-32T, PLM-2000
Downstream ApplicationsLAMP, Real-Time PCR, RT-PCR

*Dimensions and weight from OEM reference specification — confirm with Pro-Lab Direct for shipped specifications.

Frequently Asked Questions

The Mag Pro-32 processes up to 32 samples simultaneously in a single automated run. Smaller batches (1–31 samples) can also be processed using the same procedure.
A typical extraction run takes 15–40 minutes for up to 32 samples (manufacturer-stated). Exact time varies by protocol and sample type.
The Mag Pro-32 is compatible with PLM-2007 (Mag Pro Plus Automated RNA Extraction Kit), PLM-2009-32T (Mag Pro Virus DNA/RNA Extraction Kit), and PLM-2000 (Pro-Mag RNA Extraction Kit). Contact Pro-Lab Direct to confirm compatibility with other extraction kits.
The instrument itself does not require cold chain — it ships as standard freight. Compatible extraction kits should be stored per their individual product specifications.
Yes — when used with the PLM-2007 Mag Pro Plus Automated RNA Extraction Kit, the Mag Pro-32 is validated for LAMP (loop-mediated isothermal amplification) downstream applications, as well as real-time PCR and RT-PCR (manufacturer-stated).
Manual magnetic bead extraction for 32 samples typically requires 2–3 hours of hands-on bench time (operator-dependent). The Mag Pro-32 automates binding, wash, and elution — processing 32 samples in 15–40 minutes (manufacturer-stated). The instrument also includes built-in UV decontamination and protective probes to reduce carryover contamination.
Yes — PLM-NPA-32 is sold through Pro-Lab Direct, Pro-Lab's US distribution operation based in Georgetown, TX. Contact us via the quote request form or call (512) 789-5214.
The Mag Pro-32 and its compatible extraction kits are designated Research Use Only (RUO), meaning they are not FDA-cleared or approved for use in clinical diagnostic procedures. They are appropriate for research, method development, and non-clinical applications. For questions about use in your specific workflow, contact Pro-Lab Direct.

Ready to Automate Your Extraction Workflow?

request_quote

Request a Quote

Instrument pricing and TCO comparison within 1 business day.

co_present

Book a Demo

20-min instrument and kit walkthrough — virtual or on-site.

shopping_cart

Order Kits

Replenish your supply of validated extraction reagents.

support_agent

Talk to a Specialist

Applications support · (512) 789-5214

For Research Use Only — Not for Use in Diagnostic Procedures. The Mag Pro-32 (PLM-NPA-32) and compatible extraction kits are designated Research Use Only (RUO) per applicable regulatory requirements. Technical specifications marked with * are from OEM reference documentation — confirm with Pro-Lab Direct prior to purchase. The >98% magnetic bead collection efficiency is manufacturer-stated (OEM specification).